Test Num | Category | Test Description | Expected Output | How to test | Assigned-to |
1 | Installation | Make sure that the new watchdog is installed and configured successfully | |||
2 | Upgrade | Make sure that pgpool II with new watchdog can be installed on a system running pgpool II with the old watchdog | |||
3 | Configuration | Make sure that pgpool II can be configured successfully with one primary and one stand-by configuration | |||
4 | Setup | Three pgpool instanses (Host-1, Host-2, Host-3) are running on different machine using Ubutu 13:04. Connect to Host-1 and execute a sample query | Configruation | ||
4.1 | Functional testing | Shutdown Host-1's pgpool instanse and execute query again | Host-2 should take and respond to query | ||
4.2 | Functional testing | Shutdown Host-2's pgpool instanse and execute query again | Host-3 should take and respond to query | ||
4.3 | Functional testing | Start Host-1's pgpool instanse and execute query again | Need to see which host will respond to query | ||
5 | Failover scenarions / Setup | Three pgpool instanses (Host-1, Host-2, Host-3) are running on different machine using Ubutu 13:04. Connect to Host-1 and execute a sample query | Configruation | ||
5.1 | Failover scenarios | Un-Plug Host-1's network cable and execute query again | Host-2 should take and respond to query | ||
5.2 | Failover scenarios | Un-Plug Host-2's network cable and execute query again | Host-3 should take and respond to query | ||
5.3 | Failover scenarios | Plug Host-1's network cable execute query again | Need to see which host will respond to query | ||
6 | Functional testing / Setup | Three pgpool instanses (Host-1, Host-2, Host-3) are running on different machine using Ubutu 13:04. Connect to Host-1 and execute a long query | |||
6.1 | Functional testing | Shutdown / Power Off Host-1's instanse and execute query again | Host-2 should take over and start responding, need to see the already running query response. | ||
6.2 | Functional testing | Shutdown / Power Off Host-2's instanse and execute query again | Host-3 should take over and start responding, need to see the already running query response. | ||
6.3 | Functional testing | Start Host-1's pgpool instanse and execute query again | Need to see which host will respond to query | ||
7.1 | Cheking other functionality of watchdog | Changing active/standby state in case of certain faults detected | |||
7.2 | Cheking other functionality of watchdog | Automatic virtual IP address assigning synchronous to server switching | |||
7.3 | Cheking other functionality of watchdog | Automatic registration of a server as standby in recovery | |||
8 | Isolated master scenario / Setup | Three pgpool instanses (Host-1, Host-2, Host-3) are running on different machine using Ubutu 13:04. Connect to Host-1 and execute a query | |||
8.1 | Isolated master scenario | Break the connectivity between pgpool watchdog primary and stand node by bringing down connectivity on the stand-by. | Split brain testing ensures that their is only one master at a time that the clients can connect to. The stand-by should be promoted as the primary and the clients shouldn't be able to connect to the old master. | ||
9 | Networking Isolation scenarion | ||||
9.1 | |||||
10 | Database Failure | ||||
10.1 | |||||
10.2 | |||||
11 | Watchdog agent failure | ||||
11.1 | |||||
11.2 |